Thermal Mass Flow Meters

Leading Manufacturers, Exporters, Wholesaler, Retailer and Trader of Insertion Thermal Mass Flow Meter and Thermal Mass Flow Meter from Thane.

Business Type Manufacturer, Exporter, Supplier
Country of Origin India
Make CBRO
Model TMF1600 Series
Measuring Medium Various Of Gas (Except Acetylene)
Pipe Size DN10mm-DN100mm
Velocity 0.1-100Nm/s
Accuracy +/-1~2.5%
Working Temperature Sensor:-40~+220 degC Transmitter:-20~+45 degC
Working Pressure Insertion Sensor:medium pressure ≤1.6Mpa Flanged Sensor:medium pressure ≤4.0Mpa Special pressure ple
Power Supply Compact type: 24VDC or 220VAC, Power consumption ≤18W Remote type:220VAC,Power consumption ≤19W
Response Time 1s
Output 4-20mA(optoelectronic isolation,maximum load 500Ω),Pulse RS485(optoelectronic isolation) and HART
Alarm Output 1-2 line Relay, Normally Open state, 10A/220V/AC or 5A/30V/DC
Sensor Type Standard Insertion, Hot-tapped Insertion and Flanged
Construction Compact and Remote
Pipe Material Carbon Steel, Stainless Steel,Plastic etc.
Display 4 lines LCD Mass flow, Volume flow in standard condition, Flow totalizer, Date and Time, Working tim
Protection IP65

Click to view more

Insertion type thermal gas mass flow meter is one of kind mass flow meter which. Is popular in industrial applications is the way they are designed and built. The feature is no moving parts, nearly unobstructed straight through flow path, require no temperature or pressure corrections and retain accuracy over a wide range of flow rates. Straight pipe runs can be reduced by using dual-plate flow conditioning elements and installation is very simple with minimal pipe intrusions. Insertion type thermal gas mass flow meter size from DN40~DN2000mm.

Advantages :- 

Insertion type thermal gas mass flow meter advantanges :

(1)Wide range ratio 1000:1;

(2)Large diameter, low flow rate, negligible pressure loss;

(3)Direct mass flow measurement without temperature and pressure compensation;

(4)Very sensitive for low flow rate measurement;

(5)Easy to design and select, easy to install and use;

(6)Suitable for all kinds of single or mixed gas flow measurement Could measure gas with flow velocity from 100Nm/s to 0.1Nm/s, which can be used for gas leak detection;

 

(7) No pressure loss or very small pressure loss.


Application :- 

Insertion type thermal gas mass flow meter application:

Thermal gas air flow meter widely use for Electric power,water treatment,Petrochemical industry,Glass,Ceramics and Building materials industry,and mainly be used to meausre Dry gas,such as Air,Natural gas,LPG gas,Biogas,ect.But thermal gas mass flow couldn’t be used to measure Vapour, Humidity gas and Ethyne.

Installation :- 

Insertion type thermal gas mass flow meter installation:

① Regardless of whether the flowmeter is installed vertically or horizontally, keep the flowmeter in a horizontal state.

② In situations where accidental gas stop or accidental gas stop will inevitably cause major irreversible losses, bypass must be installed.

③ There should be at least a 10D straight pipe section in the front of the flowmeter and a 5D (D is the pipe diameter) straight pipe section at the rear.

④ If the instrument is installed outdoors, a sunshade should be added to avoid the sun and rain.

⑤ Make sure that there is no strong magnetic field, strong electric field and strong mechanical vibration near the flowmeter.

⑥ The static grounding of the flowmeter should be reliable, but it cannot be shared with strong current grounding.

⑦ The surrounding environment should confirm that there is no corrosive effect on aluminum alloy.

⑧ Ensure that the gas flow direction is consistent with the arrow direction on the flowmeter.

⑨ Welding operations are prohibited in an explosive environment.

 

Insertion type thermal gas mass flow meter maintenance:

 

In the daily operation of the thermal gas mass flowmeter, check and clean the flowmeter, tighten the loose parts, find and deal with the abnormality of the flowmeter in operation in time, ensure the normal operation of the flowmeter, reduce and delay the wear of components, Extend the service life of the flowmeter. Some flowmeters will become fouling after being used for a period of time, and it must be cleaned by pickling etc. depending on the degree of fouling

 

Read More...


Request to Call


Business Type Manufacturer, Exporter, Supplier
Country of Origin India
Make CBRO
Model TMF1600 Series
Measuring Medium Various Of Gas (Except Acetylene)
Pipe Size (Insert connection) DN50-DN2000mm ,In-line connection(DN10-DN2000mm)
Velocity 0.1-100Nm/s
Accuracy +/-1~2.5%
Working Temperature Sensor:-40~+220 degC Transmitter:-20~+45 degC
Working Pressure Insertion Sensor:medium pressure ≤1.6Mpa Flanged Sensor:medium pressure ≤4.0Mpa Special pressure ple
Power Supply Compact type: 24VDC or 220VAC, Power consumption ≤18W Remote type:220VAC,Power consumption ≤19W
Response Time 1s
Output 4-20mA(optoelectronic isolation,maximum load 500Ω),Pulse RS485(optoelectronic isolation) and HART
Alarm Output 1-2 line Relay, Normally Open state, 10A/220V/AC or 5A/30V/DC
Sensor Type Standard Insertion, Hot-tapped Insertion and Flanged
Construction Compact and Remote
Pipe Material Carbon Steel, Stainless Steel,Plastic etc.
Display 4 lines LCD Mass flow, Volume flow in standard condition, Flow totalizer, Date and Time, Working tim
Protection IP65

Click to view more

Flange thermal gas mass flow meter is one of kind mass flow meter which Is popular in industrial applications is the way they are designed and built. The feature is no moving parts, nearly unobstructed straight through flow path, require no temperature or pressure corrections and retain accuracy over a wide range of flow rates. Straight pipe runs can be reduced by using dual-plate flow conditioning elements and installation is very simple with minimal pipe intrusions. Flange thermal gas mass flow meter size from DN10~DN2000mm

Advantages :- 

Flange thermal gas mass flow meter advantanges :

(1)Wide range ratio 1000:1;

(2)Large diameter, low flow rate, negligible pressure loss;

(3)Direct mass flow measurement without temperature and pressure compensation;

(4)Very sensitive for low flow rate measurement;

(5)Easy to design and select, easy to install and use;

(6)Suitable for all kinds of single or mixed gas flow measurement Could measure gas with flow velocity from 100Nm/s to 0.1Nm/s, which can be used for gas leak detection;

 

(7) No pressure loss or very small pressure loss.

Application :- 

Flange thermal gas mass flow meter application:

 

Thermal gas air flow meter widely use for Electric power, Petrochemical industry, Glass, Ceramics and Building materials industry, and mainly be used to meausre Dry gas, such as Air, Natural gas, LPG gas, Biogas, ect. But thermal gas mass flow couldn’d be used to measure Vapour, Humidity gas and Ethyne.

Installation :- 

nge thermal gas mass flow meter installation:

① Observe the recommended inlet and outlet requirements.

② Good engineering practice is necessary for the associated pipe work and installation.

③ Ensure correct alignment and orientation of the sensor.

④ Take measures to reduce or avoid condensation (e.g. install a condensation trap, thermal insulation, etc.).

⑤ The maximum permitted ambient temperatures and the medium temperature range must be observed.

⑥ Install the transmitter in a shaded location or use a protective sun shield.

⑦ For mechanical reasons, and in order to protect the pipe, it is advisable to support heavy sensors.

⑧ No installation in where large vibration exists

⑨ No exposure in the environment containing a lot of corrosive gas

⑩ No sharing power supply with frequency converter, electric welding machine and other machines which can make power-line interference.

 

Daily maintenance for flange thermal gas mass flow meter:

 

In the daily operation of the thermal gas mass flowmeter, check and clean the flowmeter, tighten the loose parts, find and deal with the abnormality of the flowmeter in operation in time, ensure the normal operation of the flowmeter, reduce and delay the wear of components, Extend the service life of the flowmeter. Some flowmeters will become fouling after being used for a period of time, and it must be cleaned by pickling etc. depending on the degree of fouling

Read More...